What was found
FLOOR SUPPORT AT FS 280.00 IS CORRODED. PERFORMED CUT-OUT IAW REO 670-53-21-139 STEP 1 & 2. COMPLIED WITH STEP 3 OF REO 670-53-139 IAW NDTM PART 1, 51-20-006, NO INDICATIONS NOTED. INSTALLED REPAIR IAW WITH REO 670-53-21-139.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT AT FS 280.00 IS CORRODED. PERFORMED CUT-OUT IAW REO 670-53-21-139 STEP 1 & 2. COMPLIED WITH STEP 3 OF REO 670-53-139 IAW NDTM PART 1, 51-20-006, NO INDICATIONS NOTED. INSTALLED REPAIR IAW WITH REO 670-53-21-139.