What was found
AFTER REMOVAL OF SERVICE DOOR SILL, FOUND CORROSION ON FS 349 FLOORBEAM LATERAL FRAME AT RBL 42. FOUND TO BE OUT OF LIMITS IAW SRM 51-21-06. CUT AWAY DAMAGE ON FLOORBEAM IAW REO 601R-53-21-2320, STEP 1 & 3. COMPLIED WITH STEP 2 OF REO 601R-53-21-2320 IAW NDTM PART 1, 51-20-06 NO INDICATION NOTED AT THIS TIME. INSTALLED REPAIR.