What was found
FS 559.00+80 -559.00+96 HAS 4 EA FASTENER HOLES WITH CORROSION AT LBL 45 ON FLOOR SUPPORT. BLEND THE CORROSION IAW SRM 51-21-06. REMOVED .006" MATERIAL THICKNESS, LT .057". COMPLIED WITH REO 601R-53-51-196. FOUND TO BE SATISFACTORY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 559.00+80 -559.00+96 HAS 4 EA FASTENER HOLES WITH CORROSION AT LBL 45 ON FLOOR SUPPORT. BLEND THE CORROSION IAW SRM 51-21-06. REMOVED .006" MATERIAL THICKNESS, LT .057". COMPLIED WITH REO 601R-53-51-196. FOUND TO BE SATISFACTORY.