What was found
FS 605.00 FRAME IS CORRODED BETWEEN STR 26 AND 27L. REMOVED LOWER SECTOR OF FRAME IAW SRM 51-42-06. LOCATED ALL FASTENER HOLES IN SERVICEABLE FRAME IAW SRM 51-40-11. INSTALLED SERVICEABLE FRAME IAW SRM 51-42-06 & SRM 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FS 605.00 FRAME IS CORRODED BETWEEN STR 26 AND 27L. REMOVED LOWER SECTOR OF FRAME IAW SRM 51-42-06. LOCATED ALL FASTENER HOLES IN SERVICEABLE FRAME IAW SRM 51-40-11. INSTALLED SERVICEABLE FRAME IAW SRM 51-42-06 & SRM 51-42-21.