As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SERVICE DOOR SURROUND STRUCTURE CLIP AT FS 319.70 CORRODED. REMOVED CLIP AT FS 319.70 IAW SRM 51-42-06. INSTALLED NEW PART ALL WORK DONE IAW SRM 51-42-06 & 51-42-21. FORMED SERVICE DOOR SURROUND STRUCTURE CLIP IAW DWG 601R38303 AND SRM 51-24-21.