What was found
FLOOR SUPPORT AT FS 319 JUST FWD OF SERVICE DOOR CORRODED. REMOVED FWD FLOOR SUPPORT IAW SRM 51-42-06. DRILLED & POSITIONED NEW SERVICEABLE FLOOR SUPPORT IAW SRM 51-40-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.