What was found
FLOOR STRUCTURE CORROSION FOUND AROUND FASTENER HOLES AT RBL 45.0 BETWEEN FS 559+16 AND 559+32. REMOVED CORROSION AROUND FASTENER HOLES TO OBTAIN TOTAL DEPTH IAW SRM 51-21-00 3 TOTAL HOLES. ENGINEERING REQUIRED. REO 601R-53-51-210.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR STRUCTURE CORROSION FOUND AROUND FASTENER HOLES AT RBL 45.0 BETWEEN FS 559+16 AND 559+32. REMOVED CORROSION AROUND FASTENER HOLES TO OBTAIN TOTAL DEPTH IAW SRM 51-21-00 3 TOTAL HOLES. ENGINEERING REQUIRED. REO 601R-53-51-210.