As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR STRUCTURE HAS CORROSION AROUND FASTENER HOLE JUST FWD OF FS 559+80 AT LBL 45.0. REMOVED CORROSION FROM FASTENER HOLE TO OBTAIN TOTAL DEPTH AT LBL 45.0 JUST FWD OF 559+80 IAW SRM 51-21-00. C/W REO 601R-53-51-208 AND REO 601R-53-51-201.