What was found
RT FLOOR SILL HAS CORROSION AROUND FASTENER HOLDS BETWEEN FS 559+80 AND FS 589. BLENDED CORROSION IAW SRM 51-21-00. SRM HAS NO ALLOWABLE LIMITS. AMOUNT OF CORROSION REMOVED 0.011", REO 601R-53-00-505.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT FLOOR SILL HAS CORROSION AROUND FASTENER HOLDS BETWEEN FS 559+80 AND FS 589. BLENDED CORROSION IAW SRM 51-21-00. SRM HAS NO ALLOWABLE LIMITS. AMOUNT OF CORROSION REMOVED 0.011", REO 601R-53-00-505.