As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CARGO FLOORBEAM HAS CORROSION AROUND FASTENER HOLES AT FS 589, BETWEEN LBL 9 AND LBL 27. REMOVED CAP STRIP BETWEEN LBL 9 AND LBL 27 IAW SRM 51-42-06 AND 51-42-21. LOCATED, DRILLED AND INSTALLED NEW SERVICEABLE FS 589 FLOORBEAM CAP STRIP PN 601R35031-165 BETWEEN LBL 9 AND LBL 27 IAW SRM CH 51-42-06 AND 51-42-21.