What was found
RT FLOOR SUPPORT FWD OF SERVICE DOOR CUTOUT IS CORRODED FROM FS 310 TO FS 319. R & R FLOOR SUPPORT ANGLE IAW SRM 51-42-06. LOCATED, DRILLED NEW FLOOR SUPPORT IAW SRM 51-40-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.