As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
45 DEGREE ANGLE AT FS 562 AND 574 AT STR 17 ON LT 5 HAS 2 DOUBLE DRILLED HOLES. REMOVED ANGLE AT FS526-FS574 AT STR17 LT FWD OF AFT CARGO DOOR REF: SRM 51-42-21. FABRICATED NEW ANGLE FROM NEW STRINGER EXTRUSION PN 601R35011-43 AND INSTALLED IAW SRM 51-42-06, OP 6. REO 601R-53-61-4870. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW ASA SOP 5702.