What was found
PHOTOLUMINESCENT FLOOR TRACK LIGHTING CABIN ILLUMINATION FAILED FUNCTIONAL TEST. MEASURED AVERAGE OF LH 3 LUX, RT 3.5 LUX, MINIMUM OF 12 LUX REQUIRED. R & R ALL CABIN CEILING AND SIDEWALL LIGHT BULBS WITH NEW SERVICEABLE LIGHT BULBS (PN BR9805-007) IAW AMM 33-21-01-400-801 AND AMM 33-21-07-400-801. PERFORMED OPS TEST OF CABIN CEILING AND SIDEWALL LIGHTS IAW AMM 33-21-01-400-801. TESTED GOOD AT THIS TIME.