Service difficulty report · Bulb · Cndair CL6002B19

Difficulty date
April 8, 2013
Submitted
April 30, 2013
Operation
Air carrier
Aircraft
N925EV
Make and model
Cndair CL6002B19
Aircraft serial
7831
Aircraft time
21,533 hours, 20,575 cycles
Part
Bulb
Condition
Burned Out
Location
Emergency Light
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PHOTOLUMINESCENT FLOOR TRACK LIGHTING CABIN ILLUMINATION FAILED FUNCTIONAL TEST. MEASURED AVERAGE OF LH 3 LUX, RT 3.5 LUX, MINIMUM OF 12 LUX REQUIRED. R & R ALL CABIN CEILING AND SIDEWALL LIGHT BULBS WITH NEW SERVICEABLE LIGHT BULBS (PN BR9805-007) IAW AMM 33-21-01-400-801 AND AMM 33-21-07-400-801. PERFORMED OPS TEST OF CABIN CEILING AND SIDEWALL LIGHTS IAW AMM 33-21-01-400-801. TESTED GOOD AT THIS TIME.