What was found
FLOOR SUPPORT ANGLE AT FS 280 CORRODED. REMOVED CORRODED ANGLE. LOCATED AMD DRILLED ANGLE IAW SRM 51-40-11-001-001-A01. INSTALLED ANGLE IAW SRM 51-42-06-001-001-A01 AND DWG 670-34256.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT ANGLE AT FS 280 CORRODED. REMOVED CORRODED ANGLE. LOCATED AMD DRILLED ANGLE IAW SRM 51-40-11-001-001-A01. INSTALLED ANGLE IAW SRM 51-42-06-001-001-A01 AND DWG 670-34256.