DURING C-CHECK THE FRAME 75 VERTICAL STAB FITTING WAS FOUND TO HAVE FRETTING CORROSION BETWEEN STRINGERS 2R-2L. MX REMOVED THE CORROSION AND REPAIRED THE FITTING IAW EC5310-01317, REV C. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK THE FRAME 75 VERTICAL STAB FITTING WAS FOUND TO HAVE FRETTING CORROSION BETWEEN STRINGERS 2R-2L. MX REMOVED THE CORROSION AND REPAIRED THE FITTING IAW EC5310-01317, REV C. THE ACFT WAS APPROVED FOR RETURN TO SERVICE.