What was found
CRAWLWAY FLOOR PANEL 141ALF FWD FLOOR SUPPORT ANGLE CORRODED. REMOVED FLOOR SUPPORT IAW SRM 51-42-06. LOCATED, DRILLED & DEBURRED HOLES IAW SRM 51-40-11-001-001-A01. INSTALLED NEW FLOOR SUPPORT ANGLE IAW SRM 51-42-06-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CRAWLWAY FLOOR PANEL 141ALF FWD FLOOR SUPPORT ANGLE CORRODED. REMOVED FLOOR SUPPORT IAW SRM 51-42-06. LOCATED, DRILLED & DEBURRED HOLES IAW SRM 51-40-11-001-001-A01. INSTALLED NEW FLOOR SUPPORT ANGLE IAW SRM 51-42-06-001-001-A01.