What was found
DURING C-CHECK, INSPECTION FOUND THE CENTER OMEGA BEAM CAP CORRODED AT FRAME 59. MAINTENANCE R & R THE CENTER OMEGA BEAM IAW SRM 51-40-02. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, INSPECTION FOUND THE CENTER OMEGA BEAM CAP CORRODED AT FRAME 59. MAINTENANCE R & R THE CENTER OMEGA BEAM IAW SRM 51-40-02. ALL WORK ACCOMPLISHED AND WILL BE RELEASED AT THE END OF THE CHECK.