What was found
DURING C-CHECK, STRINGER 6R WAS FOUND TO BE CRACKED AT FRAME 14. R & R STRINGER SEGMENT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, STRINGER 6R WAS FOUND TO BE CRACKED AT FRAME 14. R & R STRINGER SEGMENT IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.