What was found
THE CREW REPORTED THAT THEY HAD SMOKE COMING FROM THE BASE OF WINDSHIELD NR 1, AND THAT IT STOPPED 1-2 MINUTES AFTER WINDSHIELD HEAT WAS TURNED OFF. THE ACFT LANDED WITH NO INCIDENT. THE CREW PLACED THE WINDSHIELD HEAT ON MEL 30-42-02, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE. MAINTENANCE INSPECTED THE ACFT AND FOUND THE GROUND LUG FOR THE NR 1 WINDSHIELD TO BE LOOSE AND PARTIALLY MELTED. MAINTENANCE R & R THE NR 1 WINDSHIELD AND GROUND LUG, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.