What was found
FOUND BS 409+128, FLOOR SUPPORT VERTICAL POST LBL 18 OTBD SIDE HAS A CRACK INDICATION .2" IN LENGTH. FAILED NDT INSPECTION. REMOVED POST IAW SRM 51-42-06 AND 51-42-21. INSTALLED IAW REO 601R-53-41-889.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND BS 409+128, FLOOR SUPPORT VERTICAL POST LBL 18 OTBD SIDE HAS A CRACK INDICATION .2" IN LENGTH. FAILED NDT INSPECTION. REMOVED POST IAW SRM 51-42-06 AND 51-42-21. INSTALLED IAW REO 601R-53-41-889.