What was found
ATTACH ANGLE TO FRAME AND THE SERVICE DOOR SILL IS CORRODED AT BS 319.7. LOCATED AND DRILLED NEW ATTACH ANGLE AND INSTALLED IAW SRM 51-40-11, 51-42-06 & 51-42-21.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ATTACH ANGLE TO FRAME AND THE SERVICE DOOR SILL IS CORRODED AT BS 319.7. LOCATED AND DRILLED NEW ATTACH ANGLE AND INSTALLED IAW SRM 51-40-11, 51-42-06 & 51-42-21.