As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY LIGHTS WILL NOT TURN ON FROM F/A'S TEST SWITCH WITH FLT DECK EMERGENCY LIGHT SWITCH IN ARM. SECURED PCB-4 IN JB-11. PERFORMED OPS CHECK OF EMERGENCY LIGHTS IAW AMM 33-24-07. OPS CHECK GOOD. PERFORMED OPS CHECKS 3 TIMES. NO DEFECTS NOTED.