What was found
FLOOR SUPPORT AT BS 349, RBL45 IS CORRODED. DRILLED NEW FLOOR SUPPORT AND INSTALLED IAW SRM 51-42-06-001-001-A01, AND DWG SH670-31950.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT AT BS 349, RBL45 IS CORRODED. DRILLED NEW FLOOR SUPPORT AND INSTALLED IAW SRM 51-42-06-001-001-A01, AND DWG SH670-31950.