As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
EMERGENCY EXIT LIGHT ON RT BOTTOM OF THE GALLEY HAS A DAMAGED FRAME WHERE ATTACHING SCREW GOES THROUGH. REMOVED AND INSTALLED A SERVICEABLE EMERGENCY EXIT LIGHT ON GALLEY SIDE PANEL IAW AMM 33-51-10-400-801 PROCEDURE 3A. OPS TESTED GOOD IAW AMM 33-51-00-710-801. DURING OPS CHECK OF THE EMERGENCY LIGHTS FOUND FLOOR LEVEL EXIT SIGN ON THE WARDROBE TO HAVE A BROKEN CONNECTOR. REPAIRED CONNECTOR BY CRIMPING A NEW PIN ONTO THE WIRE IAW ESPM 20-17-31.