As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SUPPORT FITTING AT FS 460, WL 72.50, LBL 10 IS CRACKED APPROXIMATELY .750 INCH LONG IN UPPER RADIUS. REMOVED DAMAGED SUPPORT FITTING IAW SRM 51-42-06 AND 51-42-21. DRILLED NEW SUPPORT FITTING IAW SRM 51-40-11 AND INSTALLED IAW SRM 51-42-06 & 51-42-21.