What was found
FOUND REAR PRESSURE BULKHEAD WEB, RBL 36.20, WL 82-WL 85 HAS INDICATIONS NOTED APPROX 3.0" IN LENGTH, 70 PERCENT FSH, FAILED NDT INSPECTION. LOCATED AND DRILLED REPAIR IAW REO 601R-53-61-5250. FABRICATED REMAINING PARTS & FINAL REAMED ALL HOLES FOR REPAIR TO RBL 36.2 IAW REO 601R-53-61-5250. PERFORMED CUTOUT OF BULKHEAD WEB IAW STEP 1 OF REO:601R-5361-5250. COMPLIED WITH REO:601R53-61-5250 IAW NDTM PT 1, 51-20-06.