Service difficulty report · Door Sill · Cndair CL6002C10

Difficulty date
May 2, 2014
Submitted
June 2, 2014
Operation
Air carrier
Aircraft
N707EV
Make and model
Cndair CL6002C10
Aircraft serial
10057
Aircraft time
28,601 hours, 19,932 cycles
Part
Door Sill
Condition
Corroded
Location
Service Doorway
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

SERVICE DOOR SILL CORRODED. SERVICE DOOR SILL LOWER FITTING ANGLE BEYOND ALLOWABLE LIMITS IAW SRM 53-21-23-101-001. REMOVED SERVICE DOOR-DOOR STOPS BY REMOVING 12EA BOLTS AND NUTS IAW SRM 51-41-02. REMOVED SERVICE DOOR FLOOR SILL IAW SRM 51-42-06. RECEIVED NEW SERVICEABLE DOOR FLOOR SILL LOCATED. DRILLED AND DEBURRED NEW HOLES IAW SRM 51-40-11-001-001-A01. INSTALLED LOWER ATTACH ANGLE AT SERVICE DOOR IAW SRM 51-42-06-001-001-A01 AND SRM 51-42-21-001-001-A01.