What was found
DURING C-CHECK, CORROSION FOUND ON CENTER OMEGA BEAM AT FRAME 20, 100 PERCENT THROUGH. MAINTENANCE R & R CENTER OMEGA BEAM BETWEEN FRAMES 16 AND 23 IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING C-CHECK, CORROSION FOUND ON CENTER OMEGA BEAM AT FRAME 20, 100 PERCENT THROUGH. MAINTENANCE R & R CENTER OMEGA BEAM BETWEEN FRAMES 16 AND 23 IAW SRM 51-40-02. ACFT APPROVED FOR RETURN TO SERVICE.