What was found
FOUND BS 280 FLOORBEAM ANGLE TO HAVE OVERSIZED FASTENER HOLES. REMOVED AND REPLACED IAW SRM 51-42-06-001-001-A01. MAJOR REPAIR.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND BS 280 FLOORBEAM ANGLE TO HAVE OVERSIZED FASTENER HOLES. REMOVED AND REPLACED IAW SRM 51-42-06-001-001-A01. MAJOR REPAIR.