What was found
RT FWD EQUIPMENT BAY FLOOR CRACKED UNDER ADG STOW PUMP. COMPLIED WITH EC/TC REO 670-53-11-509 AND GREO 670-53-11-509, REV B.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
RT FWD EQUIPMENT BAY FLOOR CRACKED UNDER ADG STOW PUMP. COMPLIED WITH EC/TC REO 670-53-11-509 AND GREO 670-53-11-509, REV B.