RT FLOOR SUPPORT T/E AT BS 319.7 CORRODED. REMOVED CORROSION DAMAGE IAW SRM 51-21-06-00. DAMAGE FOUND TO BE OUT OF LIMITS IAW SRM 53-00-00-01. PART REPLACED IAW SRM 51-42-07 AND DWG 601R-31148.