What was found
SEVERAL WIRES IN A BUNDLE WERE FOUND DAMAGED. ALL WIRES AT FRAME 72 AND STRINGER 14R. MAINTENANCE FOUND NO DAMAGE TO THE WIRE CONDUCTORS. REPAIRED THE DAMAGED INSULATION IAW SWPM 20-21-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SEVERAL WIRES IN A BUNDLE WERE FOUND DAMAGED. ALL WIRES AT FRAME 72 AND STRINGER 14R. MAINTENANCE FOUND NO DAMAGE TO THE WIRE CONDUCTORS. REPAIRED THE DAMAGED INSULATION IAW SWPM 20-21-00.