Service difficulty report · Fuel Sys · Cndair CL6002B19

Difficulty date
September 2, 2014
Submitted
September 5, 2014
Operation
Air carrier
Aircraft
N901EV
Make and model
Cndair CL6002B19
Aircraft serial
7616
Aircraft time
28,522 hours, 26,242 cycles
Part
Fuel Sys
Condition
Malfunctioned
Stage of operation
CL
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

400 LB IMBALANCE DURING CLIMBOUT, LT TANK, DURING FLIGHT, LEFT TANK IMBALANCE INCREASED TO AROUND 900 LBS WITH PUMPS WORKING, FOLLOWED QRH, DIVERTED. ACFT RETURNED TO DEPARTURE, EMERGENCY DECLARED. PERFORMED OPS CHECK OF FUEL TRANSFER EJECTOR PUMP IAW AMM 28-13-01. PERFORMED OPS CHECK OF SCAVENGE EJECTOR PUMP IAW AMM 28-13-22, NO DEFECTS NOTED.