As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING INSTALLATION OF THE BS 280 FLOORBEAM, FOUND A CRACKED ANGLE AT RBL38.50. REMOVED THE DAMAGED ANGLE IAW SRM 51-42-06-001-001-A01. INSTALLED SERVICEABLE ANGLE FABRICATED IAW SNIEO CC670-34010, EXCEPT WHERE ALTERNATE FASTENERS WERE SPECIFIED BY SB 670BA-53-041, REV D AND GREO 670-53-11-594. RECEIVED EO SNEIEO CC670-3410-S04 AMD COMPLIED WITH STEPS 1-3 AS NEEDED.