As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT HAS CORROSION AT BS 320 AT RBL 45. REMOVED THE SERVICE DOOR LOWER SILL ANGLE, REFERRED TO AS UPPER SUPPORT ANGLE IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. DRILLED AND INSTALLED FLOOR SILL UPPER SUPPORT KOT MOUNTING ANGLE IAW SRM 51-42-06-001-001-A01. INSTALLED LIGHTNING DIVERTER PANEL BRACKETS ON NEW LOWER SILL ANGLE IAW SRM 51-42-00-001-001 AND DWG SH690-32120.