What was found
FUSELAGE SKIN EXTERIOR SURFACE HAS MINOR CORROSION AROUND FASTENERS FROM FS 559 TO FS 559+10 BETWEEN STRS 25L AND 25R. REMOVED FASTENERS FROM FS 559 TO FS 559+10 BETWEEN STR 25L TO 25R IAW SRM 51-42-21. BLENDED AREA AROUND FASTENER HOLES REMOVING CORROSION IAW SRM 51-21-06. MATERIAL .004 WITHIN LIMITS IAW SRM 51-00-31 AND T/R 53-33. DAMAGE WAS FOUND TO BE IN A NO DAMAGE ZONE FROM FS 559 TO FS 559+10, ENGINEERING REQUIRED. COMPLIED WITH REPAIR OF CORROSION REMOVAL BETWEEN FS 559 TO FS 559+10 BETWEEN STR 25L TO 25R IAW STS EA 25-2014-293, SECTION 1, PERMANENT REPAIR 1.