What was found
FOUND FLOORBEAM CAP CORRODED SEVERELY AT BS 557 BETWEEN BL 27 AND BL 42.9. REMOVED CORRODED STRAP AND INSTALLED NEW STRAP IAW SRM 51-42-06 AND DWG 601R31025.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FOUND FLOORBEAM CAP CORRODED SEVERELY AT BS 557 BETWEEN BL 27 AND BL 42.9. REMOVED CORRODED STRAP AND INSTALLED NEW STRAP IAW SRM 51-42-06 AND DWG 601R31025.