What was found
CORROSION ON FRAME AT FS 333.00 BETWEEN LBL STGR 24 AND RBL STGR 24. REMOVED POSTS AT FS 333 RBL 20 AND LBL 20 IAW SRM 51-42-06 & 51-42-21. UPON FURTHER INVESTIGATION, FOUND TO BE BETWEEN STR 24 & 23L AND STR 24 & 23R, INSTALLED SAME SERVICEABLE VERTICAL POSTS IAW SRM 51-42-06 AND 51-42-21. REMOVED FLOOR SUPPORT BRACKET AT FS 333, BL 0 IAW SRM 51-42-06. INSTALLED FLOOR SUPPORT BRACKET AT FS 333, BL 0 IAW SRM 51-42-06. REMOVED FRAME AT FS 333 BETWEEN STRINGER 24L & 24R IAW SRM 51-42-06, 51-42-21. LOCATED AND DRILLED NEW FRAME AT FS 333 BETWEEN STRINGER 24L & 24R, PN 601R32004-55 IAW SRM 51-40-06, 51-40-11. INSTALLED NEW FRAME AT FS 333 BETWEEN STRINGERS 24L AND 24R IAW SRM 51-42-06 AND 51-42-21. COMPLETED IAW SNIEO 601R32004 S02 REV O. COMPLIED WITH REO 601R-53-21-2576 REV, 2 NOV 14.