What was found
CORROSION DAMAGE ON BS 333, FRAME AFT SIDE, STR 26L-26R. BLENDED CORROSION IAW SRM 51-12-00-001-001-A01. PERFORMED UT THICKNESS INSPECTION OF FS 333, FRAME IAW BSC NDT PROGRAM MANUAL SEC. 4.3. MIN, REMAINING THICKNESS IS .049", ORIGINAL IS .050", REMOVED IS .001", NO DAMAGE ALLOWED IN BLEND AREAS IAW SRM 53-21-06-101-002-A02.