What was found
PAX DOOR FUSELAGE HINGE AFT LUG LANDING GROOVED BY RETAINING PIN. THIS REPAIR IS CLASSIFIED AS A MAJOR REPAIR IAW SOP 5702. BLENDED DAMAGE IAW SRM 53-21-23-101-001-A01, SRM CTJ900 51-12-00-001-001-A01, TEMP REV 51-0050. COMPLIED WITH GREO 670-53-21-582, REPAIR TYPE IV STEPS 1-3, DATED 2013-03-06, REV B.