What was found
FLOOR SUPPORT ANGLE CRACKED BETWEEN BS 260 - 280 LBL 9.0. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-44-06-001-001-A01, 51-42-06-001-001-A01, 51-40-11-001-001-A01 AND SRM 51-21-16-001-001-A01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOOR SUPPORT ANGLE CRACKED BETWEEN BS 260 - 280 LBL 9.0. REMOVED AND REPLACED THE FLOOR SUPPORT IAW SRM 51-44-06-001-001-A01, 51-42-06-001-001-A01, 51-40-11-001-001-A01 AND SRM 51-21-16-001-001-A01.