What was found
RT OVERWING EMERGENCY EXIT DOOR FAILS DOOR WARNING OPS TEST. INSPECTED RT OVERWING EMERGENCY EXIT DOOR IAW AMM 52-21-00-820-801 A01 AND 52-21-00-220-801 A01 FOUND THE PROXIMITY SENSOR FITTING TO BE LOOSE. TIGHTENED RT OVERWING EMERGENCY EXIT DOOR PROXIMITY SENSOR FITTING IAW AMM 20-21-00-910-801 A01 FUNCTIONAL TEST GOOD.