What was found
LOWER WING PLANK ACCESS HOLE HAS MULTIPLE INDICATIONS NOTED ON LANDING FOR PANEL 650FB AT FWD AND OTBD EDGE, APPROXIMATELY .250" X .250" X 50 PERCENT FSH. COMPLIED WITH EC/TC EO 600-57-81. C/W IAW REO 601R-57-21-030, REV L.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LOWER WING PLANK ACCESS HOLE HAS MULTIPLE INDICATIONS NOTED ON LANDING FOR PANEL 650FB AT FWD AND OTBD EDGE, APPROXIMATELY .250" X .250" X 50 PERCENT FSH. COMPLIED WITH EC/TC EO 600-57-81. C/W IAW REO 601R-57-21-030, REV L.