What was found
CORROSION ON FS 310 FRAME AND BETWEEN STR 26L & 26R ON FRONT AND BACKSIDE OF FRAME FRAME BETWEEN 26L AND 26R HAS BEEN BLENDED PRIOR TO THIS WORK , THE CORROSION WASHER IN THE FLANGE, RADIUS ALSO THE WEB AREAS FRONT AND BACK BLENDED CORROSION IASW SRM 51-21-06-001-001-A01, FRAME 310 BETWEEN STR 26L AND 26R IS OUT OF LIMITS IAW SRM 53-21-06-101-002-A01 FORMED FRAMES ALLOWABLE DAMAGE LIMITS, GENERAL TABLE, NOTE: 1 PG 102. COMPLIED WITH STS EA32-2015-014 REPAIR, DATED 1/13/2015. COMPLIED WITH ECTC EA 32-205-014.