What was found
UPON REMOVAL OF SERVICE DOOR SILL ANGLE MOUNT FOUND LOWER SILL ANGLE TO BE CORRODED. R & R LOWER SILL ANGLE ON SERVICE DOOR IAW SRM 51-42-06-001-001-A01, AND DWG SH670-31986.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
UPON REMOVAL OF SERVICE DOOR SILL ANGLE MOUNT FOUND LOWER SILL ANGLE TO BE CORRODED. R & R LOWER SILL ANGLE ON SERVICE DOOR IAW SRM 51-42-06-001-001-A01, AND DWG SH670-31986.