What was found
UPON REMOVAL OF SERVICE DOOR SILL ANGLE MOUNT FOUND 4EA FLOOR PROTECTOR WEBS CORRODED. REMOVED 4EA FLOOR PROTECTOR WEBS FROM SERVICE DOOR ENTRANCE IAW SRM 51-42-06-001-001-A01 AND 51-42-21-001-001-A01. INSTALLED 2 FWD FLOOR PROTECTOR WEBS REF SRM 51-42-06-001-001-A01. DWG SH670-31950, REV: U. INSTALLED REMAINING AFT FLOOR PROTECTORS WEBS REF SRM 51-42-06-001-001-A01 & DWG SH 670-31950, REV: U.