What was found
RT FLOORBEAM RBL 12 AT FS 280.00 CORRODED AT LOWER SECTION. EVALUATED, FLOOR POST FOUND TO BE EXTMELY EXFOLIATED AND OUT OF LIMITS IAW SRM 53-00-00-101-001-A01. REMOVED THE FLOORBEAM IAW SRM 51-42-06-001-001-A01, 51-42-21-001-001-A01, 51-42-06-001-001-A10, 51-42-21-001-001-A01, 51-42-10-001-001-A01 AND INSTALLED IAW SRM 51-42-06-001-001-A01,51-42-21-001-001-A01, DWG 690-53-11-480. COMPLIED WITH REO 690-53-11-736.