What was found
280 CROSSBEAM CRACKED, RIGHT. REMOVED RT 280 BEAM TOP STRAP COCKPIT AFT FLOOR SUPPORT & BOTTOM CENTER SPLICE IAW SRM 51-42-20-001-001-A01. LOCATED, DRILLED AND DEBURRED NEW 280 CROSSBEAM ALSO ATTACHED NEW CROSSBEAM TO NEW WEB IAW SRM 51-42-06-001-001-A01 51-40-11-001-001-A01. INSTALLED TOP SPLICE STRAP BOTTOM CENTER SPLICE DRILLED AND INSTALLED FLOOR SUPPORT ANGLE IAW SRM 51-42-06-001-001-A01 51-42-21-001-001-A01 AND INSTALLED RT BEAM AT FS 280 IAW SAME AND DWG CC670-34010.