What was found
LT SIDE INBD FLAP, UNDER T/E HAS 2 EA DENTS. DAMAGE IS OUT OF LIMITS IAW 57-52-01-101-001-A01. REMOVED EXISTING FASTENERS FROM REPAIR AREA AND PERFORMED CUTOUT IAW SRM 57-52-01-991-812, TYPE IV, REPAIR. COMPLIED WITH SRM 57-52-01-201-001-A01, PARA 4D, 3, A, 4 IAW 900 NDTM PART 1, 51-20-006-250 NO INDICATIONS NOTED AT THIS TIME. PICKED UP ALL FASTENERS LOCATIONS IN REPAIR DOUBLER COUNTERSUNK ALL FASTENERS LOCATIONS AND APPLIED A023 FINISH TO DOUBLER IAW SRM 57-52-01-991-812, TYPE IV, REPAIR. MADE COUNTERSUNK FILLERS TO FILL EXISTING COUNTERSINK IAW SRM 51-40-11-001-001. COMPLIED WITH ECTC EO 900-57-0019 AND SRM 54-52-01, TYPE IV: APPROVED PERMANENT NON-FINISH REPAIR FOR THE ONBOARD FLAP SKIN.