What was found
RIGHT TOP AFT HOLE ON HORIZONTAL STABILIZER TRUNNION AND ACFT HORIZONTAL STABILIZER OVERSIZED TO .4125, MAX IS .380. REMOVED MOUNTING HARDWARE FROM HORIZONTAL STA IAW AMM 27-42-01-000-801. BOTTOM PINS AND TRUNNIONS TEMP INSTALLED. INSTALLED MOUNTING HARDWARE, BOTTOM TRUNNIONS FROM H8TA IAW AMM 27-42-01-400-801. C/W BSC REO 601R-55-11-512. REO 601R-55-11-512, REV HAS BEEN ACCOMPLISHED AND ALL STEPS HAVE BEEN DOCUMENTED AND SIGNED FOR ON A NRI WORK CARD.